Bronkhorst Multibus User Manual

Browse online or download User Manual for Hardware Bronkhorst Multibus. Bronkhorst Multibus User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Instruction manual
Operational instructions
for digital Multibus
Mass Flow / Pressure instruments
Doc. no.: 9.17.023AD Date: 21-04-2015
ATTENTION
Please read this instruction manual carefully before installing and operating the instrument.
Not following the guidelines could result in personal injury and/or damage to the equipment.
Head Office: Nijverheidsstraat 1a, NL-7261 AK Ruurlo, The Netherlands, Tel. +31 573 458800, [email protected]
Page view 0
1 2 3 4 5 6 ... 49 50

Summary of Contents

Page 1 - Instruction manual

Instruction manual Operational instructions for digital Multibus Mass Flow / Pressure instruments Doc. no.: 9.17.023AD Date: 21-04-2015 ATTENTION P

Page 2 - Warranty

BRONKHORST® Page 10 Operational instructions for digital multibus instruments 9.17.023 2.4 CALIBRATION WITH MATHEMATICAL FUNCTIONS 2.4.1

Page 3 - TABLE OF CONTENTS

BRONKHORST® Page 11 Operational instructions for digital multibus instruments 9.17.023 2.4.5 Using mathematical functions at a digital ins

Page 4

BRONKHORST® Page 12 Operational instructions for digital multibus instruments 9.17.023 3 PARAMETERS AND PROPERTIES 3.1 GENERAL Digital

Page 5 - 1.2 MULTIBUS TYPES

BRONKHORST® Page 13 Operational instructions for digital multibus instruments 9.17.023 These programs are on the support CD or can be

Page 6

BRONKHORST® Page 14 Operational instructions for digital multibus instruments 9.17.023 Document “917027--Manual RS232 interface” explains

Page 7 - 2 DIGITAL INSTRUMENT

BRONKHORST® Page 15 Operational instructions for digital multibus instruments 9.17.023

Page 8

BRONKHORST® Page 16 Operational instructions for digital multibus instruments 9.17.023 4 NORMAL OPERATION PARAMETERS Data Type Range read

Page 9 - CONTROL

BRONKHORST® Page 17 Operational instructions for digital multibus instruments 9.17.023 4.4 SETPOINT unsigned int 0…32000 RW N 9 1/1 4.5 F

Page 10 - XdXcXbaY ⋅+⋅+⋅+=

BRONKHORST® Page 18 Operational instructions for digital multibus instruments 9.17.023 4.8 SETPOINT SLOPE unsigned int 0…30000 RW N 10 1/2

Page 11 - 2.5.1 General information

BRONKHORST® Page 19 Operational instructions for digital multibus instruments 9.17.023 4.10.1 Dual interface operation When operating a c

Page 12 - 3.2 BRONKHORST SOFTWARE

BRONKHORST® Page 2 Operational instructions for digital multibus instruments 9.17.023 Disclaimer Even though care has been taken in the pr

Page 13 - 3.3 PARAMETER USE

BRONKHORST® Page 20 Operational instructions for digital multibus instruments 9.17.023 4.14 VALVE OUTPUT unsigned long 0…16777215 RW  Y

Page 14 - Fluid name

BRONKHORST® Page 21 Operational instructions for digital multibus instruments 9.17.023 4.20 CAPACITY UNIT INDEX unsigned char 0…4 RW  Y

Page 15 - BRONKHORST®

BRONKHORST® Page 22 Operational instructions for digital multibus instruments 9.17.023 4.21 CAPACITY UNIT unsigned char[7] see table RW 

Page 16 - 4.1 MEASURE UNIPOLAIR

BRONKHORST® Page 23 Operational instructions for digital multibus instruments 9.17.023 5 CONTROL PARAMETERS The controlling algorithm for

Page 17

BRONKHORST® Page 24 Operational instructions for digital multibus instruments 9.17.023 5.6 NORMAL STEP RESPONSE unsigned char 0…255 RW 

Page 18 - 4.10 CONTROL MODE

BRONKHORST® Page 25 Operational instructions for digital multibus instruments 9.17.023 5.11 VALVE SAFE STATE Unsigned char 0…255 RW N 301

Page 19 - 4.12 FLUID NUMBER

BRONKHORST® Page 26 Operational instructions for digital multibus instruments 9.17.023 6 ALARM / STATUS PARAMETERS 6.1 GENERAL Bronkhors

Page 20

BRONKHORST® Page 27 Operational instructions for digital multibus instruments 9.17.023 Data Type Range read/write Secured DDE Proc/par 6.3

Page 21 - APACITY UNIT INDEX

BRONKHORST® Page 28 Operational instructions for digital multibus instruments 9.17.023 6.9 ALARM DELAY TIME unsigned char 0…255 RW N 182 9

Page 22 - APACITY UNIT

BRONKHORST® Page 29 Operational instructions for digital multibus instruments 9.17.023 6.13 USING AN ALARM (EXAMPLES) Using the alarms wi

Page 23 - 5 CONTROL PARAMETERS

BRONKHORST® Page 3 Operational instructions for digital multibus instruments 9.17.023 TABLE OF CONTENTS 1 GENERAL PRODUCT INFORMATION ...

Page 24 - 1.05*response oldresponse New

BRONKHORST® Page 30 Operational instructions for digital multibus instruments 9.17.023 7 COUNTER PARAMETERS Data Type Range read/writ

Page 25 - ALVE SAFE STATE

BRONKHORST® Page 31 Operational instructions for digital multibus instruments 9.17.023 7.4 COUNTER NEW SETPOINT Unsigned int 0…32000 RW N

Page 26 - 6 ALARM / STATUS PARAMETERS

BRONKHORST® Page 32 Operational instructions for digital multibus instruments 9.17.023 7.7 COUNTER UNIT unsigned char[4] string RW N 128 1

Page 27

BRONKHORST® Page 33 Operational instructions for digital multibus instruments 9.17.023 7.9 COUNTER CONTROLLER OVERRUN CORRECTION float 0…3

Page 28 - TATUS OUT POSITION

BRONKHORST® Page 34 Operational instructions for digital multibus instruments 9.17.023 8 IDENTIFICATION PARAMETERS Data Type Range read/w

Page 29 - SING AN ALARM (EXAMPLES)

BRONKHORST® Page 35 Operational instructions for digital multibus instruments 9.17.023 8.6 IDENTIFICATION NUMBER unsigned char 0…255 RW 

Page 30 - 7 COUNTER PARAMETERS

BRONKHORST® Page 36 Operational instructions for digital multibus instruments 9.17.023 9 SPECIAL PARAMETERS Data Type Range read/write Se

Page 31 - 7.6 COUNTER UNIT INDEX

BRONKHORST® Page 37 Operational instructions for digital multibus instruments 9.17.023 Flatconductorcablemain PC boardfieldbusinterface1234

Page 32 - 7.8 RESET COUNTER ENABLE

BRONKHORST® Page 38 Operational instructions for digital multibus instruments 9.17.023 9.4.3 Example of using the virtual ‘analog mode ju

Page 33

BRONKHORST® Page 39 Operational instructions for digital multibus instruments 9.17.023 10 SPECIAL INSTRUMENT FEATURES 10.1 ZEROING Not ap

Page 34 - 8 IDENTIFICATION PARAMETERS

BRONKHORST® Page 4 Operational instructions for digital multibus instruments 9.17.023 6.5 ALARM MAXIMUM LIMIT...

Page 35 - EVICE TYPE

BRONKHORST® Page 40 Operational instructions for digital multibus instruments 9.17.023 10.1.2 Zeroing with digital communication The foll

Page 36 - 9 SPECIAL PARAMETERS

BRONKHORST® Page 41 Operational instructions for digital multibus instruments 9.17.023 11 MANUAL INTERFACE: MICRO-SWITCH AND LED’S 11.1 GENE

Page 37 - S1S2S3S4

BRONKHORST® Page 42 Operational instructions for digital multibus instruments 9.17.023 11.2 LED’S INDICATIONS 11.2.1 LED indications mode

Page 38

BRONKHORST® Page 43 Operational instructions for digital multibus instruments 9.17.023 11.2.2 LED indications mode (DeviceNet MBC3) for

Page 39 - 10.1 ZEROING

BRONKHORST® Page 44 Operational instructions for digital multibus instruments 9.17.023 11.2.3 LED indications using micro-switch at normal

Page 40 - ESTORE PARAMETER SETTINGS

BRONKHORST® Page 45 Operational instructions for digital multibus instruments 9.17.023 For MBC3 type of instruments the “configuration mode

Page 41 - 11.1 GENERAL

BRONKHORST® Page 46 Operational instructions for digital multibus instruments 9.17.023 11.3.2 Readout bus-address/MAC-ID and baudrate: Pre

Page 42 - 11.2 LED’S INDICATIONS

BRONKHORST® Page 47 Operational instructions for digital multibus instruments 9.17.023 11.3.3 Change bus-address/MAC-ID and baudrate: Pres

Page 43 - Indication

BRONKHORST® Page 48 Operational instructions for digital multibus instruments 9.17.023 11.4 MICRO-SWITCH USE FOR READING/CHANGING CONTROL

Page 44

BRONKHORST® Page 49 Operational instructions for digital multibus instruments 9.17.023 12 TESTING AND DIAGNOSTICS All digital instruments

Page 45 - 11.3.1 General

BRONKHORST® Page 5 Operational instructions for digital multibus instruments 9.17.023 1 GENERAL PRODUCT INFORMATION 1.1 INTRODUCTION Thi

Page 46

BRONKHORST® Page 50 Operational instructions for digital multibus instruments 9.17.023 13 SERVICE For current information on Bronkhorst a

Page 47

BRONKHORST® Page 6 Operational instructions for digital multibus instruments 9.17.023 1.3 REFERENCES TO OTHER APPLICABLE DOCUMENTS Manual

Page 48 - 11.4.2 Change control mode:

BRONKHORST® Page 7 Operational instructions for digital multibus instruments 9.17.023 2 DIGITAL INSTRUMENT 2.1 GENERAL A digital instrume

Page 49 - 12 TESTING AND DIAGNOSTICS

BRONKHORST® Page 8 Operational instructions for digital multibus instruments 9.17.023 Digital instruments can be operated by means of: 1.

Page 50 - +31 573 45 88 39

BRONKHORST® Page 9 Operational instructions for digital multibus instruments 9.17.023 2.3 MEASURE AND CONTROL FUNCTIONAL BLOCK DIAGRAM Th

Comments to this Manuals

No comments